| BPB STEEL FRAME FIRE RATED SYSTEMS: | |||||||||||||||||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| 15 | 1 | TGS15A | -/15/15 | BPB Aquastop | 1 | 10 | NLB | Single | 64x32 | - | 600 | - | - | 200 | - | No STC |
38 |
| 30 | 2 | TGS30 | -/30/30 | BPB Regular | 1/1 | 13 | NLB | Single | 64x32 | - | 600 | - | - | 200 | - | 42 | 39 |
| 30 | 3 | TGSL30 | 30/30/30 | BPB Firestop | 1/1 | 13 | LB | Single | 92x35 | - | 600 | - | - | 200 | - | - | 40 |
| 30 | 3 | TGSL30a | 30/30/30 | BPB Firestop | 1/1 | 16 | LB | Single | 92x35 | - | 600 | - | - | 200 | - | - | 41 |
| 30 | 4 | TGSL30b | 30/30/30 | BPB Firestop | 2/2 | 10/13 | LB | Single | 92x32 | - | 600 | - | - | 200 | - | - | 42 |
| 60 | 3 | TGS60a | -/60/60 | BPB Firestop | 1/1 | 16 | NLB | Single | 92x32 | - | 600 | R1.8 | - | 200 | - | 40 | 43 |
| 60 | 3 | TGS60b | -/60/60 | BPB Duraline | 1/1 | 13 | NLB | Single | 62x32 | - | 600 | R1.8 | - | 200 | - | 39 | 44 |
| 60 | 4 | TGSL60 | 60/60/60 | BPB Firestop | 2/2 | 13 | LB | Single | 92x32 | - | 600 | R1.8 | - | 200 | - | 48 | 45 |
| 120 | 4 | TGS120 | -/120/120 | BPB Firestop | 2/2 | 13 | NLB | Single | 62x32 | - | 600 | - | - | 200 | - | - | 46 |
Or download the above Summary Table in PDF format here.
-
Adobe Acrobat
The PDF files on this page require the free Acrobat Reader from the Adobe website. Download it here. -
Masterspec Login
Masterspec subscribers can access BPB Plasterboard in Masterspec by logging in here. -
Regulations
BPB plasterboard is manufactured to AS/NZS 2588:1998 and meets the requirements of the New Zealand Building Code, complying with NZS 3604... more.